KTL1600-1400 double-temperature zone tubular furnace

Product name: KTL1600-1400 double temperature zone tube furnace

Model number: KTL1600-1400

Minimum starting quantity: 1

Product Summary:
KTL1600-1400 double temperature area tube furnace with silicon molybdenum rod and silicon carbon rod as heating elements, there are two heating areas, using double shell structure and yu electric temperature control instrument, each heating area can be 30 sections of program temperature control, phase shift trigger, silicon control control, furnace using alumina polycrystalline fiber material, the highest temperature of 1600℃ and 1400℃

product description
KTL1600-1400 double temperature zone tube furnace detailed introduction:

KTL1600-1400 double temperature zone tube furnace with silicon molybdenum rod and silicon carbon rod as heating elements, There are two heating zones, Using the double shell structure and yu electric temperature control instrument, Each heating area can perform 30 sections of program temperature control, Phase shift triggered, SCR controlled, The furnace is made of alumina polycrystalline fiber material, With stainless steel flanges, The stainless steel flange is fitted with an air nozzle, valve and pressure gauge, The vacuum degree can reach 10-3 Pa, The furnace is of the horizontal type, Two temperature zones can be independently controlled and set at different temperatures, convenient to use, simplicity of operator, The furnace has the advantages of temperature field equilibrium, low surface temperature, fast lifting temperature rate, energy saving and so on, It is the ideal product for universities, scientific research institutes and industrial and mining enterprises to do high temperature atmosphere sintering, atmosphere reduction, CVD experiment and vacuum annealing.

1.can connect to the computer
Software control system: the furnace is equipped with communication interface and software, can directly through the computer control the parameters of the furnace, and can observe from the computer on the stove PV and SV temperature value and the operation of the instrument, the actual heating curve computer real-time drawing, and can save each moment temperature data, can be out at any time.(pick out and buy)
Open cover protection system: the furnace is equipped with a travel switch, when the furnace cover is opened, automatically cut off the power supply, effectively ensure the safety of users.
Seal system: double-layer silicone O-ring extrusion seal is used between the furnace pipe and the flange, which is easy to remove, repeatable withdrawal and discharge, good air tightness, and can ensure that the 12-hour pressure gauge pointer does not deflection.
Vacuum system (optional): it can be equipped with TW-1.5A vacuum pump and 10-1Pa vacuum pump or 10-4Pa imported molecular pump.

Furnace material: using high quality alumina polycrystalline fiber material furnace, do not drop powder, material insulation performance, high reflectivity, temperature field balance, resistance to heat rise and cooling shrinkage ability is strong.
Heating elements: silicon-carbon rod, silicon-molybdenum rod.
Leakage protection function: the furnace is equipped with leakage air switch, when the furnace body leakage automatic power, to ensure the safety of use.
Gas supply system (selected): the furnace is equipped with a floormeter, customers can control the flow rate of gas through the floatmeter or proton flow meter (please see the options for details).
Flange: using double ring sealing technology, effectively improve the atmosphere of flange, flange is equipped with a variety of joints, can be connected to resistance vacuum meter, KF 25 bellows and can be easy to remove the hinge type.
Flange bracket: the flange is supported by the flange bracket, which effectively eliminates the stress of the flange frame on the corundum tube, and extends the service life of the corundum tube.

Detailed technical parameters of KTL1600-1400 double-temperature zone tubular furnace:

Modelpowerfurnace tube sizesupply voltage
KTL1600-1400-607KWDia60(OD) X1200mm220V
KTL1600-1400-807KWDia80(OD)X1200220V

Phase number: single phase
Heating element, the first temperature zone of silicon molybdenum rod second temperature zone: silicon carbon rod heating element heating element
The second temperature zone: the silicon carbon rod
Heating element: the first temperature zone of silicon molybdenum rod, the second temperature zone: silicon carbon rod

control method:
Adopt temperature control instrument (standard)
Optional Japanese conductive program temperature control instrument
(1)The temperature control of section 30 program can only be adjusted by PID.
(2)With the over temperature protection when the overtemperature or break protection electric furnace heating circuit automatically cut off, (when the electric furnace temperature exceeds 1420 degrees or the thermocouple is off, the AC relay on the main circuit will automatically cut off, the main circuit is off, the panel ON lamp OFF, OFF light on, the limited protection electric furnace).
(3)With 485 communication interface (standard when choosing software)
(4)has the function of power off protection, that is, when the power is off and then start the furnace, the program does not rise from the starting temperature, but from the furnace temperature when the power is off.
(5)The instrument has the function of temperature self-setting

FP93 temperature control instrument (Japan) (replace imported instrument with additional charge)
(1)The temperature control of 40-segment programs can be divided into 4,2 and 1 groups of programs. If it is divided into 4 groups of programs, each program is 10 segments,
(2)6 sets of PID control, low, medium and high temperature can be used with a set of PID, so that each temperature segment can be controlled very accurately.
(3)with over temperature protection overtemperature or break protection electric furnace heating circuit automatically cut off, (when the electric furnace temperature exceeds 1420 degrees or the thermocouple burned off, the AC relay on the main circuit will be automatically disconnected, the main circuit disconnected, panel ON light off, OFF light on, limited protection electric furnace).
(4)Instruments are available in degrees Fahrenheit (F) and degrees Celsius (C)
(5)With 485 communication interface (standard when choosing software)
(6)has the automatic shutdown function
(7)can store multiple groups of programs, can be arbitrarily out when using.
(8)has the function of power off protection, that is, when the power is off and then start the furnace, the program does not rise from the starting temperature, but from the furnace temperature when the power is off.
(9)The instrument has the output power, the number of program execution and execution time, and the program in the up, constant temperature and cooling state.
(10)the meter has the jump function (that is, the meter can jump this step to directly perform the next step.
(11)The instrument has the function of temperature self-setting.