KTL1700-1400 double-temperature zone tubular furnace

Product name: KTL1700-1400 double temperature zone tube furnace

Model number: KTL1700-1400

Minimum starting quantity: 1

Product Summary:
KTL1700-1400 double temperature area tube furnace with 1800 type silicon molybdenum rod and silicon carbon rod as heating elements, there are two heating areas, using double shell structure and yu electric temperature control instrument, each heating area can be 30 program temperature control, phase shift trigger, silicon control control, furnace using alumina polycrystalline fiber material, the highest temperature of the first and second temperature areas 1700℃ and 1400℃

product description
KTL1700-1400 double temperature area tube furnace detailed introduction:

KTL1700-1400 three-temperature zone tubular furnace with 1800 type silicon molybdenum rod and silicon carbon rod as heating elements, There are two heating zones, Using the double shell structure and yu electric temperature control instrument, Each heating area can perform 30 sections of program temperature control, Phase shift triggered, SCR controlled, The furnace is made of alumina polycrystalline fiber material, With stainless steel flanges, The stainless steel flange is fitted with air nozzle, valve and pressure gauge, The vacuum degree can reach 10-3 Pa, The furnace is of the horizontal type, Two temperature zones can be independently controlled and set at different temperatures, convenient to use, simplicity of operator, The furnace has the advantages of temperature field equilibrium, low surface temperature, fast lifting temperature rate, energy saving and so on, It is an ideal product for universities, scientific research institutes and industrial and mining enterprises to do high temperature atmosphere sintering, atmosphere reduction, CVD experiment and vacuum annealing.
Software control system: the furnace is equipped with communication interface and software, can directly through the computer control furnace parameters, and can observe from the computer on the furnace PV and SV temperature value and the operation of the instrument, the actual heating curve computer real-time drawing, and can save each moment temperature data, can be out at any time.(apolegamy)

Open cover protection system: the furnace is equipped with a travel switch, when the furnace cover is opened, automatically cut off the power supply, effectively ensure the safety of users.
Seal system: the double-layer silicone O-ring extrusion seal between the furnace pipe and the flange, easy to remove, repeatable removal, good air tightness, can ensure that the 12-hour pressure gauge pointer does not deflection.
Vacuum system: can be equipped with TW-1.5A vacuum pump and 10-1Pa vacuum pump or 10-4Pa imported molecular pump.
Furnace material: alumina fiber furnace material, do not drop powder, material insulation performance, high reflectivity, temperature field balance, heat resistance and cooling shrinkage ability is strong.
Heating elements: silicon-carbon rod, silicon-molybdenum rod.
Leakage protection function: the furnace is equipped with leakage air switch, when the furnace body leakage automatic power, to ensure the safety of use.
Gas supply system: The furnace is equipped with a floormeter, and the customer can control the flow rate of the gas through the floormeter or proton flow meter (please see the options for details).
Flange: using double ring sealing technology, effectively improve the atmosphere of flange, flange is equipped with a variety of joints, can be connected to resistance vacuum meter, KF 25 bellows and can be easy to remove the hinge type.
Flange bracket: the flange is supported by the flange bracket, which effectively eliminates the stress of the flange frame on the corundum tube, and extends the service life of the corundum tube.

Technical parameters of KTL1700-1400 double-temperature zone tubular furnace:

Modelpowerfurnace tube sizesupply voltage
 KTL1700-1400-60     7KWDia 60(OD) X1200 mm220V
 KTL1700-1400-807KWDia80(OD)X1200mm220V
Phase number: single phase
Heating element: the first temperature zone: 1800 type silicon molybdenum rod
 the second temperature zone: silicon carbon rod

control method
Adopt instrument for temperature control (standard)
Optional Japanese conductive program temperature control instrument
(1)The temperature control of section 30 program can only be adjusted by PID.
(2)with over temperature protection overtemperature or break when the electric furnace heating circuit automatically cut off, (when the electric furnace temperature exceeds 1720 degrees or the thermocouple burned off, the AC relay on the main circuit will be automatically disconnected, the main circuit disconnected, panel ON light off, OFF light on, limited protection electric furnace).
(3)With 485 communication interface (standard when choosing software)
(4)has the function of power off protection, that is, when the power is cut off and the power is started, the program does not rise from the starting temperature, but from the furnace temperature when the power is cut off.
(5)The instrument has the function of temperature self-setting

(1)The temperature control of 40 segment programs can be divided into 4,2 and 1 groups of programs. If it is divided into 4 groups of programs, each program is 10 segments,
(2)6 sets of PID control, low, medium and high temperature can be used with a set of PID, so that each temperature segment can be controlled very accurately.
(3)with over temperature protection protection over temperature or break when the electric furnace heating circuit automatically cut off, (when the electric furnace temperature exceeds 1720 degrees or the thermocouple burned off, the AC relay on the main circuit will be automatically disconnected, the main circuit disconnected, the panel ON light off, OFF light on, limited protection electric furnace).
(4)Instruments are available in degrees Fahrenheit (F) and degrees Celsius (C)
(5)With 485 communication interface (standard match when purchasing software)
(6)has the automatic shutdown function
(7)can store multiple groups of programs, can be arbitrary when using the call out.
(8)has the function of power off protection, that is, when the power is cut off and the power is started, the program does not rise from the starting temperature, but from the furnace temperature when the power is cut off.
(9)The instrument has the output power, the number of program execution and execution time, and the program in the up, constant temperature and cooling state.
(10)the meter has the jump function (that is, the meter can jump this step to directly perform the next step.
(11)The instrument has the function of temperature self-setting.

Scroll to Top